Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Arq. bras. oftalmol ; 87(4): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520241

ABSTRACT

ABSTRACT Purpose: This study aimed to report an experiment designed to determine anatomical changes in porcine corneas following placement of a novel polymer implant into the cornea. Methods: An ex vivo porcine eye model was used. A novel type I collagen-based vitrigel implant (6 mm in diameter) was shaped with an excimer laser on the posterior surface to create three planoconcave shapes. Implants were inserted into a manually dissected stromal pocket at a depth of approximately 200 μm. Three treatment groups were defined: group A (n=3), maximal ablation depth 70 μm; Group B (n=3), maximal ablation depth 64 μm; and group C (n=3), maximal ablation depth 104 μm, with a central hole. A control group (D, n=3) was included, in which a stromal pocket was created but biomaterial was not inserted. Eyes were evaluated by optical coherence tomography (OCT) and corneal tomography. Results: Corneal tomography showed a trend for a decreased mean keratometry in all four groups. Optical coherence tomography showed corneas with implants placed within the anterior stroma and visible flattening, whereas the corneas in the control group did not qualitatively change shape. Conclusions: The novel planoconcave biomaterial implant described herein could reshape the cornea in an ex vivo model, resulting in the flattening of the cornea. Further studies are needed using in vivo animal models to confirm such findings.


RESUMO Objetivo: Relatar um experimento projetado para determinar alterações anatômicas em córneas porcinas após a colocação de um novo implante de polímero na córnea. Métodos: Foi utilizado olho de porco ex vivo. Um novo agente modelador biocompatível, de colágeno tipo 1, com 6mm de diâmetro foi moldado com excimer laser em sua face posterior, para criar três formatos planocôncavos. Os implantes foram inseridos dentro de um bolsão, dissecado manualmente, a 200 micrômetros (μm). Foram definidos três grupos de tratamento: grupo A (n=3), teve a profundidade máxima de ablação de 70 μm; o grupo B (n=3), profundidade máxima de ablação de 64 μm; e o grupo C (n=3), profundidade máxima de ablação de 104 μm, com buraco central. O grupo controle, D (n=3), foi incluído, com a criação do bolsão estromal, porém sem inserir o material. A avaliação desses olhos foi realizada por tomografia de coerência óptica (OCT) e por tomografia corneana. Resultados: A tomografia corneana mostrou uma tendência para diminuição da ceratometria média em todos os 4 grupos. A tomografia de coerência óptica mostrou córneas com implantes localizados no estroma anterior e aplanamento visível, enquanto as córneas não mudaram qualitativamente o formato no grupo controle. Conclusões: O novo implante de biomaterial planocôncavo descrito aqui foi capaz de remodelar a córnea em modelo de animal ex vivo, resultando no aplanamento corneano. Novos estudos são necessários usando modelos animais in vivo para confirmar tais achados.

2.
Rev. bras. oftalmol ; 82: e0043, 2023. tab, graf
Article in English | LILACS | ID: biblio-1507881

ABSTRACT

ABSTRACT LASIK is a refractive surgical procedure in which a corneal flap is created to expose the corneal stromal bed. Preoperative estimation of corneal flap thickness is necessary to calculate the percentage tissue altered in LASIK, an important quantitative risk factor for ectasia. The objective of this study was to assess flap thickness and calculate percentage tissue altered to check if unexpectedly thicker flaps and higher percentage tissue altered could pose as risk factors of ectasia. Four subjects (eight eyes) were submitted to mechanical LASIK in 2009 and 2010. Pre and postoperative clinical and tomographic data were reviewed. Mean preoperative estimated percentage tissue altered was 39.18±1.31%, which was borderline for increased ectasia risk when considering the limit of 40%. However, when considering the postoperatively measured flap thickness, the actual mean percentage tissue altered turned out to be 45.17 ± 4.13%, which was significantly higher than predicted preoperatively (p=0.002). Unexpectedly higher postoperative percentage tissue altered may be responsible for corneal ectasia after mechanical LASIK.


RESUMO A LASIK é um procedimento cirúrgico refrativo, no qual um retalho corneano é criado para expor o leito estromal corneano. A estimativa pré-operatória da espessura do retalho corneano é necessária para calcular o percentual de tecido alterado no LASIK, um importante fator de risco quantitativo para ectasia. O objetivo deste estudo foi avaliar a espessura do retalho e calcular o percentual de tecido alterado para verificar se retalhos inesperadamente mais espessos e percentuais de tecido alterado mais altos poderiam representar fatores de risco de ectasia. Quatro indivíduos (oito olhos) foram submetidos à LASIK mecânica em 2009 e 2010. Dados clínicos e tomográficos pré e pós-operatórios foram revisados. A média de percentual de tecido alterado pré-operatória estimada foi de 39,18±1,31%, limítrofe para risco aumentado de ectasia quando considerado o limite de 40%. No entanto, ao considerar a espessura do retalho medida no pós-operatório, o percentual de tecido alterado médio real foi de 45,17±4,13%, ou seja, significativamente maior do que o previsto no pré-operatório (p=0,002). O percentual de tecido alterado pós-operatóriao inesperadamente mais alto pode ser responsável pela ectasia da córnea após LASIK mecânico.


Subject(s)
Humans , Male , Female , Adult , Postoperative Complications , Surgical Flaps/pathology , Keratomileusis, Laser In Situ/adverse effects , Keratomileusis, Laser In Situ/methods , Dilatation, Pathologic/etiology , Lasers, Excimer/adverse effects , Refractive Errors , Cornea/surgery , Cornea/pathology , Corneal Topography/methods , Tomography, Optical Coherence , Dilatation, Pathologic/diagnosis , Refractive Surgical Procedures/methods , Lasers, Excimer/therapeutic use
3.
Rev. bras. oftalmol ; 82: e0021, 2023. graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1441325

ABSTRACT

RESUMO O FemtoLasik é uma das técnicas mais empregadas em cirurgia refrativa, por seus bons resultados refracionais, sua previsibilidade, sua reprodutibilidade e sua segurança. Tem alto grau de satisfação, com rápida recuperação visual. Apesar de as taxas de complicações do FemtoLasik serem pequenas, intercorrências podem existir. O objetivo deste trabalho foi relatar um caso de uma complicação na dissecção da lamela por Lasik com laser de femtossegundo com consequente rasgadura da lamela, sendo aplicado Excimer Laser com mitomicina C 0,02%. O retratamento foi realizado com ablação de superfície (ceratectomia fotorrefrativa) guiada por frente de onda, evoluindo com boa qualidade visual final.


ABSTRACT Femtolasik is one of the most used techniques in refractive surgery due to good refractive results, predictability, reproducibility, and safety, achieving excellent results and a high degree of satisfaction. Although the complication rates are small, it is worth noting that there may be intercurrences. The objective of this work is to report a case of complication in the dissection of the lamella of laser in situ keratomileusis (Lasik) with Femtosecond laser, and subsequent lamella tear. Excimer Laser was applied with mitomycin 0.02% and re-approached with wavefront guided surgery, evolving with good final visual quality.

4.
Arq. bras. oftalmol ; 83(1): 76-81, Jan.-Feb. 2020. tab, graf
Article in English | LILACS | ID: biblio-1088947

ABSTRACT

ABSTRACT The point of centration for refractive surgery is a theme of great importance that generates considerable discussion among specialists and surgeons in the field. Notably, any changes in light can alter the size of the pupil, and the visual axis of the fixation line to the fovea is unique in each patient. A variety of options have been described in the literature with respect to centration in refractive surgery, and the results differ among these methods. No consensus has been established regarding the ideal refractive surgery technique for evaluation of centration in each patient that will yield a satisfactory surgical result.


RESUMO O ponto de centralização da cirurgia refrativa é tema de grande importância e gera muita discussão entre especialistas e cirurgiões da área. Afinal, qualquer alteração na luz pode alterar o tamanho da pupila, além disso, o eixo visual da linha de fixação para a fóvea é particular em cada paciente. Existem opções para centralização em cirurgia refrativa com resultados diferentes na literatura. Ainda não há consenso sobre a melhor técnica em cirurgia refrativa que avalie cada caso específico visando um resultado cirúrgico final satisfatório.


Subject(s)
Humans , Pupil/physiology , Cornea/surgery , Keratomileusis, Laser In Situ/methods , Lasers, Excimer , Refraction, Ocular , Cornea/pathology , Fixation, Ocular
5.
MedUNAB ; 21(1): 31-45, 2018.
Article in English | LILACS | ID: biblio-970612

ABSTRACT

Introduction. Corneal power determination after refractive surgery with excimer laser is complex. Different alternatives with the use of corneal tomography have been used for this measurement. Objective. To evaluate various methods of determination of corneal power in patients undergoing photorefractive surgery, including diagnostic tests with quantitative measurements. Methodology. This is a retrospective observational study. We included patients undergoing photorefractive surgery with refractive results and post-operative corneal tomography taken at least ten weeks after surgery. Results. In myopic eyes, significant differences were found in the value determined by the keratometry derived from the clinical history when compared with the average post-operative manual keratometry, the simulated 32keratometry and the Mean Pupil Power of the Sirius®tomograph. On another note, when averaging the mean post-operative manual keratometry with the post-operative Mean Pupil Power (value called Kpopaverage 1) and comparing it with the keratometry derived from the clinical history method, no statistically significant differences were observed in myopic patients. Likewise, when averaging the simulated post-operative keratometry of the Sirius® equipment with the post-operative Mean Pupil Power (value called "Kpop average 2") and comparing it with the keratometry derived by the method of the clinical history, no statistically significant differences were observed in myopic patients. On the other hand, in hyperopic eyes and those with mixed astigmatism, mean errors from post-operative Mean Pupil Power, in comparison to the keratometry derived by clinical history method, were not significantly different from the errors when comparing the "Kpop average 1" and the "Kpop average 2"with keratometry derived by the clinical history method. Conclusions. In myopic eyes the post-operative corneal power determinations with the "Kpop average 1" and "Kpop average 2" are closer to the keratometry derived by clinical history method than to measurements from the average post-operative manual keratometry, the post-operative simulated keratometry or the Mean Pupil Power of the Sirius® equipment.


Introducción. La determinación del poder corneal, después de la cirugía refractiva con láser excimer, es difícil. Diferentes alternativas con el uso de tomógrafos corneales se han utilizado para esta medición. Objetivo. Evaluar diversos métodos de determinación del poder corneal en pacientes operados de cirugía fotorrefractiva, incluyendo pruebas diagnósticas con medidas cuantitativas. Metodología. Estudio retrospectivo de pacientes operados de cirugía fotorrefractiva que tuvieran resultados refractivos y tomografía corneal post-operatoria al menos diez semanas luego de cirugía. Resultados. En los ojos miopes se encontraron diferencias significativas en el valor determinado por la queratometría derivada de la historia clínica al compararla con la queratometría manual promedio postoperatoria, la queratometría simulada y el Mean Pupil Power del tomógrafo Sirius®. Por otra parte, al promediar la queratometría manual promedio postoperatoria con el Mean Pupil Power postoperatorio (valor denominado Kpop promedio 1) y compararla con la queratometría derivada por el método de la historia clínica, no se observaron en los pacientes miopes diferencias estadísticamente significativas. Asimismo, al promediar la queratometría simulada postoperatoria del equipo Sirius® con el Mean Pupil Power postoperatorio (valor denominado Kpop promedio 2) y compararla con la queratometría derivada por el método de la historia clínica tampoco se observaron en los pacientes miopes diferencias estadísticamente significativas. Por otro lado, en los ojos hipermétropes y con astigmatismo mixto, los promedios de los errores del Mean Pupil Power postoperatorio, con respecto a la queratometría derivada por el método de la historia clínica, no fueron significativamente diferentes de los errores al comparar la Kpop promedio 1 y la Kpop promedio 2 con la queratometría derivada por el método de la historia clínica. Conclusiones. En ojos miopes las determinaciones del poder corneal postoperatorio con las Kpop promedio 1 y Kpop promedio 2 se aproximan más a la queratometría derivada por el método de la historia clínica que a las mediciones de la queratometría manual promedio postoperatoria, la queratometría simulada postoperatoria o el Mean Pupil Power del equipo Sirius®. [Jaramillo LC, Galvis V, Tello A, Camacho PA, Castillo A, Pareja LA. Determinación del poder corneal con un tomógrafo corneal luego de cirugía refractiva con láser excimer. MedUNAB. 2018;21(1):16-30. doi:1029375/01237047.2397].


Introdução. A determinação da potência corneana, após a cirurgia refrativa com excimer láser, é difícil. Foram usadas diferentes alternativas com o uso de tomógrafos de córnea para esta medição. Objetivo. Avaliar vários métodos de determinação da potência corneana em pacientes submetidos à cirurgia fotorrefrativa, incluindo testes diagnósticos com medidas quantitativas. Métodos. Este é um estudo observacional retrospectivo. Foram incluídos pacientes submetidos à cirurgia fotorrefrativa com resultados refrativos e topografía corneana pós-operatória pelo menos um mês após a cirurgia. Resultados. Nos olhos míopes foram encontradas diferenças significativas no valor determinado pela ceratectomia derivada da história clínica, quando comparada com a média da ceratectomia manual pós-operátoria, a ceratectomia simulada e o Mean Pupil Power do tomógrafo Sirius®. Por outro lado, ao calcularmos a média da ceratectomia manual pós-operatória com o Mean Pupil Power pós-operatório (valor denominado Kpop média 1) e compará-la com a ceratectomia pelo método da história clínica, não foram observadas diferenças estatisticamente significantes nos pacientes miopes. Da mesma forma, ao calcular a média da ceratectomia pós-operatória simulada do equipamento Sirius® com o Mean Pupil Power pósoperatório (valor denominado Kpop média 2) e comparála com a ceratectomia derivada do método de história clínica, não foram observadas diferenças estatisticamente significantes nos pacientes miopes. Por outro lado, em olhos hipermetrópicos e com astigmatismo mixto, as médias de erros do Mean Pupil Power pós-operatório, em relação à ceratectomia derivada pelo método da história clínica, não foram significativamente diferentes dos erros na comparação do Kpop média 1 y la Kpop média 2 com a ceratectomia derivada pelo método da história clínica. Conclusões. Nos olhos míopes, as determinações de potência corneana pósoperatória com Kpop média 1 e Kpop média 2 estão mais próximas da ceratectomia derivada pelo método da história clínica do que das medidas de ceratectomia manual média pós-operatória, da ceratectomia simulada pós-operatória ou Mean Pupil Power do equipamento Sirius®. [Jaramillo LC, Galvis V, Tello A, Camacho PA, Castillo A, Pareja LA. Determinação da potência corneana com uma topografia de córnea após cirurgia refrativa com excimer láser. MedUNAB. 2018;21(1):16-30. doi:1029375/01237047.2397].


Subject(s)
Corneal Topography , Refractive Errors , Photorefractive Keratectomy , Cornea , Refractive Surgical Procedures , Lasers, Excimer
6.
Arq. bras. oftalmol ; 76(6): 335-338, nov.-dez. 2013. graf, tab
Article in Portuguese | LILACS | ID: lil-701281

ABSTRACT

OBJETIVO: Avaliar comparativamente os resultados cirúrgicos, na técnica LASIK, realizando com laser de femtosegundo e microcerátomo mecânico. MÉTODOS: Estudo clínico, prospectivo, comparativo, randomizado e mascarado de 32 olhos (16 pacientes). Cada paciente foi submetido a diferentes técnicas para o LASIK, em um dos olhos foi utilizado o microcerátomo HansatomeTM Bausch & Lomb (grupo microcerátomo) e no outro foi utilizado femtosegundo FEMTO LDV TM Ziemer (grupo femtosegundo). A triagem ocorreu no setor de Cirurgia Refrativa do Hospital de Olhos do Paraná entre 07/2010 e 09/2010. Os critérios de inclusão foram miopia menor que 6,00 D, astigmatismo menor que 3,00 D, menor que 5,00 D de hipermetropia, refração estável, diâmetro corneano menor que 11 mm, descontinuação de lente de contato sete dias antes da avaliação pré-operatória, acuidade visual de no mínimo 20/20 em ambos os olhos. As variáveis analisadas no pré-operatório entre os grupos, femtosegundo e microcerátomo foram: acuidade visual sem correção e com correção, equivalente esférico, aberrações totais de alta ordem, acuidade visual de baixo contraste, preferência do paciente e complicações. RESULTADOS: Todas as variáveis estudadas foram similares nos dois grupos. CONCLUSÃO: Não foi possível observar neste estudo, diferenças significativas entre os grupos analisados.


PURPOSE: To assess LASIK flaps made by femtosecond laser and mechanical microkeratome. METHODS: Clinical, prospective, randomized, masked study of 32 eyes (16 patients). Both eyes of all patients were operated, each patient underwent different techniques for lasik. Microkeratome HansatomeTMBausch & Lomb (group microkeratome) was used in one eye and femtosecond laser Femto LDVTMZiemer (group femtosecond) was used for the fellow eye. Patients were selected from the Refractive Surgery service of the Eye Hospital of Paraná between July 2010 and September 2010. Inclusion criteria were myopia less than 6.00 D, astigmatism less than 3.00 D, hyperopia less than 5.00 D, stable refraction over one year, corneal diameter smaller than 11 mm, discontinuation of contact lenses seven days before the preoperative evaluation, corrected visual acuity of at least 20/20. Eyes were randomly allocated for each technique. The studied variables were: visual acuity with and without correction, residual refractive error, high order aberrations, low contrast visual acuity, complications and subjective patient preference. RESULTS: All studied variables were similar between the two groups. CONCLUSION: We could not demonstrate any difference between the studied groups.


Subject(s)
Humans , Keratomileusis, Laser In Situ/methods , Lasers, Excimer/therapeutic use , Myopia/surgery , Surgical Flaps/surgery , Contrast Sensitivity , Cornea/surgery , Corneal Stroma/surgery , Keratomileusis, Laser In Situ/instrumentation , Postoperative Period , Prospective Studies , Statistics, Nonparametric , Time Factors , Treatment Outcome , Visual Acuity
7.
Arq. bras. oftalmol ; 75(2): 126-130, mar.-abr. 2012. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-640160

ABSTRACT

PURPOSE: To assess the outcomes of intrastromal corneal ring (ISCR) implantation for the treatment of corneal ectasia. METHODS: Thirty-five consecutive patients with secondary corneal ectasia treated with keraring intrastromal corneal ring segment implantation aided by intralaser femtosecond technique (K-ICRS-FS) were evaluated. Visual acuity (logMAR), refraction and astigmatism vector analysis were measured preoperatively and 3 months postoperatively using vector analysis as described by some authors. RESULTS: Visual acuity improved from 0.40 ± 0.20 to 0.25 ± 0.13 logMAR (p=0.0002), with reduction of the spherical equivalent from -5.41 ± 4.78 D to -2.83 ± 3.29 D (P=0.0002). Mean astigmatism reduction was 3.92 ± 2.52 D. K maximum decreased from 51.65 ± 5.83 D preoperatively to 48.58 ± 5.54 D (p=0.001) 3 months after the surgery and K minimum decreased from 45.92 ± 4.64 D to 43.96 ± 5.06 D (p=0.0041). There were no intraoperative or postoperative complications. CONCLUSION: Intrastromal corneal ring implantation with the use of a femtosecond laser was a safe procedure, with low risk of complications and significant improvement on visual acuity and topographic data in this seeting of patients with secondary corneal ectasia.


OBJETIVO: Avaliar os resultados do implante de anel intraestromal (Keraring®) com laser de femtosegundo para o tratamento de ectasias corneanas (ceratocone e dege­neração marginal pelúcida). MÉTODO: Estudo retrospectivo em 35 pacientes consecutivos com ectasia corneana submetidos a implante de anel intracorneano (Keraring®). Acuidade visual (logMAR), refração, ceratometria e a análise vetorial do astigmatismo foram as variáveis analisadas. O túnel para o implante dos segmentos foi confeccionado com laser de femtosegundo. Os pacientes foram seguidos pelo período mínimo de três meses. RESULTADOS: A acuidade visual corrigida melhorou de 0,40 ± 0,20 para 0,25 ± 0,13 (p=0,0002), com diminuição do equivalente esférico de -5,41 ± 4,78 D no pré-op. para -2,83 ± 3,29 D no pós-op. (p=0,0002) e média de 3,92 ± 2,52 D na análise vetorial do astigmatismo. O K máximo variou de 51,65 ± 5,83 D para 48,58 ± 5,54 D (p=0,000) e o K mínimo de 45,92 ± 4,64 D para 43,96 ± 5,06 D (p=0,0041). Não houveram complicações intra ou pós-operatórias). CONCLUSÃO: Os resultados deste estudo mostraram que o implante do anel intra es­tromal é um procedimento seguro, com baixo risco de complicações, tendo determinado importante melhora na acuidade visual e dos dados topográficos de pacientes com ectasias corneanas.


Subject(s)
Adult , Female , Humans , Keratoconus/surgery , Prosthesis Implantation/methods , Corneal Topography , Follow-Up Studies , Refraction, Ocular , Retrospective Studies , Severity of Illness Index , Treatment Outcome , Visual Acuity
8.
Arq. bras. oftalmol ; 75(1): 33-37, jan.-fev. 2012. graf, tab
Article in English | LILACS | ID: lil-622543

ABSTRACT

PURPOSE: To determine the ten-year visual results and outcomes of excimer laser phototherapeutic keratectomy (PTK) for recurrent corneal erosions. METHODS: Twenty-six eyes of 23 patients with recurrent corneal erosions were treated by PTK from 1996 to 2000 at the Goiania Eye Institute, Brazil. All eyes had failed to respond to conventional therapy. Data regarding preoperative and postoperative best-spectacle-corrected visual acuity (BSCVA), spherical equivalent (SE), symptomatic relief, incidence of recurrence, and complications arising from the laser treatment were analyzed. The mean duration of symptoms prior to PTK was 18 months (range, 8 to 36 months). The corneal epithelium was debrided, and laser ablation was performed to a depth of 5 micron with an ablation zone of 7 to 9 mm, using the Technolas 217C Plano Scan excimer laser. Mean postoperative follow-up was 12 years (range, 10 to 14 years). RESULTS: At the last follow-up visit, 15 eyes (57.69%) were symptomsfree. Five eyes (19.2%) had occasional mild symptoms of irritation and photophobia upon awakening. Recurrence of painful corneal erosions occurred in six eyes (23.07%), which required a PTK retreatment. Twenty-four eyes had a preserved or improved BCVA, while 2 eyes showed deterioration of 1 line on Snellen test. Eleven eyes (42.3%) had no change in SE, and the others (57.69%) had a change of less than +/-0.75 diopters (D). There were no major complications during the follow-up period. CONCLUSION: Ten-year data show that PTK is a safe, fast, effective and minimal invasive choice of treatment for recurrent corneal erosions in patients who do not respond to conventional treatments.


OBJETIVO: Determinar os resultados visuais após dez anos de seguimento da ceratectomia fototerapêutica (PTK) com excimer laser para erosões recorrentes de córnea. MÉTODOS: Vinte e seis olhos de 23 pacientes portadores de erosões recorrentes de córnea foram tratados com PTK entre 1996 e 2000 no Instituto de Olhos de Goiânia, Brasil. Nenhum olho havia respondido às terapias convencionais. Dados pré-operatórios e pós-operatórios referentes à melhor acuidade visual corrigida (MAVC), equivalente esférico (EE), alívio dos sintomas, incidência de recorrência e complicações oriundas do tratamento a laser, foram analisadas. A média de duração dos sintomas antes do PTK foi de 18 meses (variando entre 8 a 36 meses). O epitélio da córnea foi debridado e a ablação realizada a uma profundidade de 5 µm e diâmetro de 7 a 9 mm, usando o excimer laser Technolas 217C Plano Scan. O seguimento médio foi de 12 anos (variando entre 10 e 14 anos). RESULTADOS: No último exame, 15 olhos (57,69%) estavam livres dos sintomas. Cinco olhos (19,2%) apresentavam sintomas, discretos e ocasionais, de irritação e fotofobia ao levantar. Recorrência de erosões dolorosas ocorreu em 6 olhos (23,07%), o que necessitou de retratamento com PTK. Vinte e quatro olhos mantiveram ou melhoraram sua MAVC, enquanto que 2 olhos perderam 1 linha de visão pela tabela de Snellen. Onze olhos (42,3%) mantiveram o mesmo EE e os outros (57,69%) apresentaram alterações inferiores a +/-0,75 dioptrias (D). Nenhuma complicação significativa foi observada durante o período de seguimento. CONCLUSÕES: Os dados de 10 anos mostram que o PTK é uma opção segura, rápida, eficaz e pouco invasiva para o tratamento de erosões recorrentes de córnea em pacientes que não respondem bem às terapias convencionais.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Corneal Diseases/surgery , Lasers, Excimer , Photorefractive Keratectomy/methods , Corneal Topography , Follow-Up Studies , Postoperative Complications , Recurrence , Treatment Outcome , Visual Acuity
9.
Surg. cosmet. dermatol. (Impr.) ; 3(3): 213-218, set. 2011. ilus, tab, graf
Article in English, Portuguese | LILACS-Express | LILACS | ID: lil-606391

ABSTRACT

Introdução: O vitiligo é cosmeticamente desfigurante e pode causar significativa morbidade psicológica. A maioria das terapêuticas requer tratamento longo e pode levar a resultados decepcionantes. Recentemente, o Eximer laser-308nm revelou ser efetivo no tratamento de vitiligo. Objetivo: Neste estudo retrospectivo foram analisadas a eficácia e satisfação dos pacientes que usaram Eximer laser-308nm no tratamento de manchas de vitiligo em diferentes regiões anatômicas. Métodos: Participaram 123 pacientes com vitiligo generalizado ou localizado, apresentando 321 lesões. Os pacientes foram tratados em clínica privada de 2007 a 2010. A análise da resposta ao tratamento foi feita por comparação de registros clínicos e fotográficos obtidos antes e após o tratamento, por dois examinadores independentes. Resultados: Setenta e sete dos 123 pacientes apresentaram repigmentação superior a 60%; 26 entre 40 e 59%; e 20% tiveram repigmentação inferior a 39%. Lesões na face responderam melhor ao tratamento do que as localizadas em outras regiões corporais. As áreas menos sensíveis foram cotovelos, mãos e pés. De forma geral, os pacientes ficaram satisfeitos com o tratamento. Conclusões: O uso do Excimer laser para tratamento do vitiligo foi eficaz, seguro e levou a resultados cosmeticamente satisfatórios com melhora da autoestima dos pacientes

10.
Arq. bras. oftalmol ; 74(2): 102-105, Mar.-Apr. 2011. graf, tab
Article in Portuguese | LILACS | ID: lil-593130

ABSTRACT

OBJETIVO: Comparar a pressão intraocular (PIO) pré e pós-LASIK, correlacionando-as com as mudanças da espessura corneana central (ECC) e ceratometria simulada média (K), assim como verificar o resultado de fórmula corretiva proposta anteriormente. MÉTODOS: Estudo longitudinal, prospectivo, realizado em pacientes submetidos a LASIK. Os pacientes foram submetidos ao exame oftalmológico completo, no pré operatório e após 2 meses da cirurgia. A pressão intraocular foi avaliada com tonômetro de aplanação de Goldmann entre 9 h e 11 h da manhã, a ceratometria simulada média foi avaliada por meio de topografia corneana e a espessura corneana central foi aferida por paquímetro ultrassônico, sendo considerada a média de três aferições. Foram excluídos dois pacientes com cirurgias ou doenças oculares prévias, e uso prévio de corticosteróide tópico nos últimos três meses. As cirurgias foram realizadas de acordo com os procedimentos-padrão. Foi utilizada a fórmula [PIO real = PIO aferida + (540 - ECC)/71 + (43 - K)/2,7 + 0,75 mmHg] proposta para correção da pressão intraocular pós-operatória. RESULTADOS: Quinze olhos de oito pacientes foram avaliados, a idade variou de 24 a 46 anos (média: 31,37 ± 7,27). Foi observada diferença estatisticamente significante entre as medidas da pressão intraocular, de ceratometria simulada média e da espessura corneana central pré e pós-LASIK. (p=0,0001). Foi observado que para cada 1D corrigida, há uma subestimação, em média, de 1,06 ± 0,59 mmHg (0,11 a 1,89 mmHg). A aplicação da fórmula corretiva levou a 80 por cento dos olhos com a tonometria estimada entre ± 2,50 mmHg da pré-operatória, no entanto, quando comparada com a tonometria pré-operatória, estas são estatisticamente diferentes (p=0,0266). CONCLUSÕES: Os olhos submetidos a LASIK apresentaram PIO pós-operatória menor do que a pré-operatória. A pressão intraocular pôde ser moderadamente correlacionada com a espessura corneana central e fracamente com a ceratometria simulada média. Não houve correlação entre a profundidade de ablação e a variação da pressão intraocular, no pós-operatório. Usando a fórmula proposta, pudemos averiguar que 80 por cento dos pacientes apresentaram pressão intraocular entre ± 2,50 mmHg da pré-operatória.


PURPOSE: To compare the intraocular pressure (IOP) pre and post LASIK, correlating it to changes in central corneal thickness (CCT) and average simulated keratometry (K), as well as verifying the results of a corrective formula previously proposed. METHODS: Longitudinal prospective study conducted in outpatients that underwent to LASIK. Patients underwent complete ophthalmic examination, previously and 2 months after the surgery. Intraocular pressure was evaluated with Goldmann applanation tonometer between 9 am and 11 am, average simulated keratometry was evaluated using corneal topography and central corneal thickness was measured with ultrasound pachymetry, been considered the average of three measurements. Two patients were excluded due to surgery or eye disease, and previous use of topical steroids over the past three months. The surgeries were performed according to standard procedures. The formula [real IOP = IOP measured + (540 - ECC)/71 + (43 - K)/2.7 + 0.75 mmHg] proposed for correcting intraocular pressure was used. RESULTS: Fifteen eyes of eight patients were evaluated, age ranged from 24 to 46 years (mean: 31.37 ± 7.27). There was a statistically significant difference between the measurements of intraocular pressure, central corneal thickness and average simulated keratometry pre and post-LASIK. (p=0.0001). It was observed that each 1D corrected underestimated the IOP 1.06 ± 0.59 mmHg (0.11 a 1.89 mmHg). The use of the corrective formula lead to 80 percent of eyes within 2.50 mmHg of preoperative intraocular pressure. Although, the two sets of data are statistically different (p=0.0266). CONCLUSIONS: Post LASIK eyes presented lower intraocular pressure than preoperatively. Intraocular pressure was moderately correlated to central corneal thickness and weakly correlated to average simulated keratometry. With the use of the corrective formula, we were able to determine that 80 percent were within 2.50 mmHg of the preoperative intraocular pressure.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Young Adult , Intraocular Pressure/physiology , Keratomileusis, Laser In Situ , Algorithms , Astigmatism/surgery , Corneal Topography , Cornea/pathology , Myopia/surgery , Organ Size , Postoperative Period , Prospective Studies , Tonometry, Ocular , Treatment Outcome
11.
Arq. bras. oftalmol ; 73(4): 323-328, July-Aug. 2010. ilus, tab
Article in English | LILACS | ID: lil-560603

ABSTRACT

PURPOSE: To assess clinical outcomes and changes on higher-order aberrations (HOA) after wavefront-guided laser in situ keratomileusis (LASIK) and photorefractive keratectomy (PRK) for correction of myopia and myopic astigmatism performed by training-surgeons. METHODS: One hundred and seventy patients had customized LASIK (207 eyes) and PRK (103 eyes) performed by surgeons in-training using the LADARVision 4000 (Alcon, Fort Worth, TX). Preoperative and 1, 3, 6 and 12 months postoperative data of spherical equivalent (SE), best spectacle-corrected visual acuity (BSCVA) and uncorrected visual acuity (UCVA) were analysed. Wavefront changes were determined using the LADARWave Hartmann-Shack wavefront aberrometer and the pupil size was scaled for 6.5 mm. RESULTS: The mean SE in the LASIK group was -3.04 ±1.07 D and in the PRK group was -1.60 ± 0.59 D. At 1-year follow-up, (80.6 percent) (LASIK) and (66.7 percent) (PRK) were within ± 0.50 D of the intended refraction. The UCVA was 20/20 or better in (58.1 percent) (LASIK) and (66.7 percent) (PRK) of the operated eyes. A statistically significant positive correlation was found between achieved versus attempted refractive correction in both groups: LASIK (r=0.975, P<0.0005) and PRK (r=0.943, P<0.005). The higher-order aberrations (HO) RMS and coma did not changed signicantly in the PRK group between preoperative and 1-year follow-up. In the LASIK group the HO RMS and coma changed between preoperative and 1-month postoperative but remained statistically unchanged during 1-year follow-up. The spherical aberration showed statistically significant changes in both groups. CONCLUSIONS: Wavefront-guided LASIK and photorefractive keratectomy performed by training-surgeons were found to be similarly effective, predictable and stable.


OBJETIVO: Avaliar os resultados clínicos e mudanças nas aberrações de alta-ordem (HOA), após ceratomileuse assistida por excimer laser in situ (LASIK) e ceratectomia fotorrefrativa (PRK) guiados por frentes de onda para correção da miopia e astigmatismo miópico realizada por cirurgiões em treinamento. MÉTODOS: Estudo prospectivo de 170 pacientes submetidos a LASIK personalizado (207 olhos) e PRK (103 olhos) realizados por cirurgiões em treinamento utilizando o LADARVision 4000 (Alcon, Fort Worth, TX). Dados do equivalente esférico (SE), melhor acuidade visual corrigida (BSCVA) e acuidade visual não corrigida (UCVA) foram analisados no pré-operatório e com 1, 3, 6 e 12 meses de pós-operatório. As alterações de frentes de onda foram determinadas usando o aberrômetro Hartmann-Shack (LADARWave)e o tamanho da pupila foi determinado para 6,5 mm. RESULTADOS: A média do SE no grupo de LASIK foi -3,04 ± 1,07 D e no grupo de PRK foi -1,60 ± 0,59 D. No seguimento de um ano, (80,6 por cento) (LASIK) e (66,7 por cento) (PRK) estavam dentro de ± 0,50 D de equivalente esférico. A UCVA foi de 20/20, ou melhor, em (58,1 por cento) (LASIK) e (66,7 por cento) (PRK) dos olhos operados. Foi encontrada correlação positiva estatisticamente significante entre correção refrativa alcançada versus pretendida em ambos os grupos: LASIK (r=0,975, P<0,0005) e PRK (r=0,943, P<0,005). O HO RMS e coma não alteraram significantemente no grupo PRK entre pré-operatório e após um ano de seguimento. No grupo de LASIK o HO RMS e o coma alteraram entre pré-operatório e 1º mês de pós-operatório, mas permaneceram estatisticamente inalterados durante um ano de seguimento. Houve alterações estatisticamente significantes da aberração esférica em ambos os grupos. CONCLUSÕES: O LASIK e o PRK guiados por frentes de onda, realizados por cirurgiões em treinamento, mostraram ser similarmente eficazes, previsíveis e estáveis.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Young Adult , Astigmatism/surgery , Keratomileusis, Laser In Situ/methods , Myopia/surgery , Photorefractive Keratectomy/methods , Corneal Wavefront Aberration , Follow-Up Studies , Linear Models , Ophthalmology/education , Prospective Studies , Time Factors , Treatment Outcome , Visual Acuity
12.
São Paulo; s.n; 2010. [141] p. ilus.
Thesis in Portuguese | LILACS | ID: lil-579190

ABSTRACT

OBJETIVO: Avaliar a eficácia, estabilidade, previsibilidade e segurança da ceratectomia fotorrefrativa (PRK) guiada pelas frentes de onda corneana para o tratamento da hipermetropia secundária à ceratotomia radial (CR). MÉTODOS: Foram avaliados prospectivamente 61 olhos de 39 pacientes consecutivos, submetidos a PRK personalizado com o laser Esiris-Schwind. A técnica constou de desepitelização mecânica, fotoablação, e utilização de mitomicina C (MMC) 0,02% por 20 ou 40 segundos. A MMC foi aplicada por 40 segundos em 17 olhos (27,9%) que haviam sido submetidos a ablações mais profundas do que 100 ?m ou apresentavam córneas previamente suturadas. As avaliações pós-operatórias foram realizadas após sete dias, um, seis, 12 e 24 meses. Todos os olhos foram avaliados após um ano e dois anos. RESULTADOS: O intervalo médio entre a CR e o PRK foi de 18,8 anos ± 3,8 (DP); o equivalente esférico (EE) médio antes da ceratotomia radial era -4,10 dioptrias (D) ± 1,44. As medidas prévias ao PRK mostraram EE médio de +4,17 D ± 1,97; astigmatismo médio de -1,39 D ± 1,04; AV com correção (AVcc) média de 0,161 ± 0,137 (logMAR); e curvatura corneana média de 35,85 ± 3,60 D. Os resultados encontrados dois anos após a cirurgia foram: EE médio de 0,14 ± 0,99 D (p < 0,001); astigmatismo médio de -1,19 ± 1,02 D (p = 0,627); AV sem correção (AVsc) média de 0,265 ± 0,196 (p < 0,001); AVcc média de 0,072 ± 0,094 (p < 0,001); e curvatura corneana média de 39,01 ± 3,18 D (p < 0,001). AVsc igual ou melhor a 20/25 foi observada em 38% dos olhos e igual ou melhor a 20/40 em 69%. A AVcc melhorou em 62,3% dos olhos, sendo que 21 olhos (34,4%) melhoraram uma linha e outros 17 olhos (27,9%), duas ou mais linhas. Um olho (1,6%) perdeu duas linhas devido ao astigmatismo irregular ocasionado por opacificação corneana periférica. Outro olho perdeu três linhas pelo desenvolvimento de ectasia corneana entre seis e 24 meses, devido ao alargamento progressivo de uma incisão radial inferior...


PURPOSE: To assess the efficacy, stability, predictability and safety of corneal wavefront-guided photorefractive keratectomy (PRK) for correcting hyperopia after radial keratotomy (RK). METHODS: In a prospective study, 61 eyes of 39 consecutive patients were treated with PRK using an Esiris-Schwind excimer laser. Corneal epithelium was mechanically removed, followed by photoablation and use of 0.02% mitomycin C (MMC) for 20 or 40 seconds. MMC was used for 40 seconds in 18 eyes (27.9%) which underwent ablations deeper than 100 micron or had previous corneal sutures. Postoperative evaluations were performed after seven days, six, 12 and 24 months. All patients were followed up for two years. RESULTS: The mean time between RK and PRK was 18.8 years ± 3.8 (SD); mean spherical equivalent (SE) before RK was -4.10 diopters (D) ± 1.44. Before PRK, the mean SE was +4.17 D ± 1.97, mean astigmatism was -1.39 D ± 1.04, the mean best-corrected visual acuity (BCVA) was 0.161 ± 0.137 (logMAR) and the mean corneal curvature was 35.85 ± 3.60 D. At 24 months, mean SE was 0.14 ± 0.99 D (p < 0.001), mean astigmatism was -1.19 ± 1.02 D (p = 0.627), mean UCVA was 0.265 ± 0.196 (p < 0.001), mean BSCVA was 0.072 ± 0.094 (p < 0.001) and the mean corneal curvature was 39.01 ± 3.18 D (p < 0.001). UCVA was 20/25 or better in 38% of eyes and 20/40 or better in 69%. BCVA improved in 62.3% of eyes, with 21 (34.4%) gaining one line and 17 (27.9%), two or more lines. One eye (1.6%) lost two lines due to irregular astigmatism and peripheral haze. Another eye lost three lines due to keratectasia occurring between six and 24 months resulting from widening of an inferior radial incision that was later sutured. Thirty eyes (49.2%) were within ± 0.50 D of intended SE and 45 (73.8%) were within ± 1.00 D. From six to 24 months, the mean SE...


Subject(s)
Astigmatism , Hyperopia , Keratotomy, Radial , Lasers, Excimer , Photorefractive Keratectomy
13.
Rev. bras. oftalmol ; 68(5): 271-277, set.-out. 2009. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-536428

ABSTRACT

OBJETIVO: Avaliar as alterações que ocorrem na sensibilidade corneanas após as cirurgias de LASIK e PRK MÉTODOS: Estudo prospectivo onde foram avaliados 60 olhos de 30 pacientes submetidos a LASIK bilateral simultaneamente e mais 30 olhos de 15 pacientes submetidos a PRK bilateral simultaneamente. De acordo com a quantidade de ablação intra-operatórias, os olhos foram divididos em dois grupos: Grupo 1 (menor que 40 µm) e Grupo 2 (Maior que 40 µm). A sensibilidade corneana foi medida na região central da córnea pelo estesiometro Cochet Bonnet® no pré operatório e após 30, 90 e 180 dias da cirurgias. RESULTADOS: A sensibilidade corneana na LASIK apresentou-se diminuída durante os três primeiros meses retornando as valores pré operatórios aos 6 meses; E de acordo com a quantidade de ablação o Grupo 1 apresentou diferença estatisticamente significante em relação ao Grupo 2 durante os três primeiros meses; No entanto a PRK recuperou seus valores pré operatório aos três meses e de acordo com a quantidade de ablação o Grupo 1 apresentou diferença estatisticamente significante somente no primeiro mês de pós operatório. CONCLUSÃO: A LASIK apresentou sensibilidade menor em relação ao PRK durante os 3 primeiros meses e somente aos 6 meses os valores da sensibilidade corneana foram similares; Os resultados também sugerem que a quantidade de ablação está relacionada com a diminuição da sensibilidade corneana durante os primeiros meses em ambas as técnicas cirúrgicas, principalmente na LASIK.


PURPOSE: To evaluate the alterations that occur on the cornea sensitivity after Lasik and PRK surgery. METHODS: Prospective studies have evaluated60 eyes from 30 patients subjected simultaneously to bilateral Lasik and 30 eyes from 15 patients subjected simultaneously to bilateral PRK. According to the amount of inner operatory ablation the eyes were divided into two groups: Group I (< 40 µm) and group II (> 40µm). The cornea sensitivity was measured in the central region of the cornea on the pre operatory and then again at 30, 90 and 180 days after the surgery with the esthesiometer. RESULTS: The cornea sensitivity in Lasik presented itself in a minor way during the first three months, returning to pre operatory values at six months; and according to the amount of ablation group I presented statistically significant difference in comparison to group II during the first three months; however PRK recovered its pre operatory values at three months and according to the amount of ablation group I presented statistically significant difference only on the first month of pre operatory. CONCLUSION: Lasik showed the least sensitivity in comparison to PRK during the first three months, only at six months the sensitivity values were similar to each other; the results suggest that the result of ablation endangers the cornea sensitivity during the first months on both surgical techniques especially Lasik.


Subject(s)
Cornea/physiopathology , Corneal Diseases/etiology , Keratomileusis, Laser In Situ , Ophthalmic Nerve , Photorefractive Keratectomy , Sensation
14.
Arq. bras. oftalmol ; 72(2): 247-250, mar.-abr. 2009. ilus
Article in Portuguese | LILACS | ID: lil-513899

ABSTRACT

A ceratopigmentação, ou tatuagem do estroma corneano, é método utilizado para tratar cosmeticamente lesões corneanas como leucoma e coloboma traumático de íris. Pode-se realizar a aplicação do pigmento pela micropunção estromal ou associada à ceratectomia ou ceratoplastia lamelar. Demonstramos um caso de tatuagem estromal corneana associada a ceratoplastia lamelar em paciente com leucoma corneano extenso, com irregularidade de superfície, que não tolerava lentes de contato e sem prognóstico visual. Houve também correção do estrabismo divergente no mesmo tempo cirúrgico. Após um ano de seguimento, o pigmento mantém-se impregnado no estroma corneano, proporcionando bom aspecto estético. Em conclusão, a técnica da tatuagem associada ao transplante lamelar da córnea constitui bom método para tratamento cosmético do leucoma central com irregularidades da superfície corneana.


Stromal cornea tattooing has been used for esthetic treatment of corneal scars as leukoma and iris coloboma. The coloring agent can be applied through stromal micropuncture or associated with lamellar keratectomy or keratoplasty. We report a case of stromal tattooing associated with lamellar keratectomy in a patient's eye that had extensive leukoma and irregular corneal surface. Visual acuity in the operated eye was no light perception and the patient did not tolerate the use of cosmetic contact lens. Correction of divergent strabismus was also performed during the surgery. After one year follow-up, the ink is still impregnated in the corneal stroma, giving a good esthetic aspect. In conclusion, the technique of corneal tattooing associated with lamellar keratectomy is a good method for the cosmetic treatment of central leukoma with corneal irregularity.


Subject(s)
Humans , Male , Middle Aged , Corneal Stroma , Corneal Transplantation , Corneal Opacity/surgery , Tattooing , Combined Modality Therapy , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL